Aritech CS175 Guida di Installazione

Navigare online o scaricare Guida di Installazione per Sistemi di controllo di accesso Aritech CS175. Aritech CS175 Installation guide Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 167
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti

Sommario

Pagina 1 - LCD/LED Installation Guide

CS175-275-575-875 LCD/LED Installation Guide Document Version 2.4 : July 2003

Pagina 2

10 CS175-275-575-875 Installation Guide 3 DEFAULT COUNTRY CODES Country Country code User code Installer code Download Access Code Baltic states 03

Pagina 3 - CONTENTS

100 CS175-275-575-875 Installation Guide Terminal Description POS Connect to the KP POS terminal of the CSx75. Current draw is 30 mA. COM Connect to

Pagina 4

CS175-275-575-875 Installation Guide 101 17.4.2 Programming the zone configuration and partition All zones are programmed via the CSx75 panel and ke

Pagina 5

102 CS175-275-575-875 Installation Guide Location 194 Starting zone (one segment, ND) Segment 1 0 Starting zone is zone 1 1 Starting zone is zone

Pagina 6

CS175-275-575-875 Installation Guide 103 " For Belgium the following parameters must be configured: Segment 1: Number of minutes, for non-fire t

Pagina 7 - NTRODUCING THE CSX75 SYSTEM

104 CS175-275-575-875 Installation Guide Transmitter Action Door/Window Activate tamper switch by removing the cover. Door/Window with external cont

Pagina 8

CS175-275-575-875 Installation Guide 105 2. The keypad prompts you to enter a module number. 3. Enter the module number and press #. The module num

Pagina 9 - 2 DEFAULT CODES

106 CS175-275-575-875 Installation Guide 18 CS216 HARDWARE ZONE EXPANDER The CS216 is a microprocessor-controlled 16-zone expander for the CSx75 contr

Pagina 10 - 3 DEFAULT COUNTRY CODES

CS175-275-575-875 Installation Guide 107 Starting Zone Number Module Number DIP Switch 1 DIP Switch 2 DIP Switch 3 DIP Switch 4 DIP Switch 5 9 23 On

Pagina 11 - 4 INSTALLATION GUIDELINES

108 CS175-275-575-875 Installation Guide Terminal Description Connector on the left side DATA Connect to the KP DATA terminal of the CSx75. (See the

Pagina 12

CS175-275-575-875 Installation Guide 109 19 CS534 AUDIO BOARD The CS534 is a two-way audio (voice) communicator for the CSx75 alarm panel. Once the a

Pagina 13

CS175-275-575-875 Installation Guide 11 4 INSTALLATION GUIDELINES This installation manual details the installation and programming of the CSx75 usin

Pagina 14 - 4.4 Installation schematic

110 CS175-275-575-875 Installation Guide 19.1.2 Call back mode If programmed for this mode, the CS534 starts a timer when the control panel releases t

Pagina 15 - INSTALLING THE CONTROL UNIT

CS175-275-575-875 Installation Guide 111 SPK+ SPK- Connect to the speaker(s). Maximum speaker wire run: 1000’ (300m). Minimum speaker rating: 5 Watt

Pagina 16

112 CS175-275-575-875 Installation Guide before the time-out period (location 3, segment 1), the system returns to the stand-by mode and waits for a n

Pagina 17

CS175-275-575-875 Installation Guide 113 99 Terminates session and returns to the stand-by mode and waits for a new trip. MICROPHONE CONTROL (ZONIN

Pagina 18

114 CS175-275-575-875 Installation Guide Tone Description One high tone for 100 mS Time remaining indicator “A “ One mid tone for 100 mS Time rema

Pagina 19

CS175-275-575-875 Installation Guide 115 • On: listen-in only mode: this allows the central station to listen to the activity at the premises. • Of

Pagina 20

116 CS175-275-575-875 Installation Guide Seg 3 Call back windows timer (Default = 5 minutes) • Determines the amount of time, in one-minute increment

Pagina 21

CS175-275-575-875 Installation Guide 117 Location 5 Programming X-10 address for output 1 (two segments, ND) " An X-10 interface module, such

Pagina 22 - 7 6 4 3 2 1

118 CS175-275-575-875 Installation Guide 20 CS507 OUPUT EXPANDER BOARD The CS507 is an auxiliary module used to expand the capabilities of the CSx75 c

Pagina 23 - 4.5.1 Inputs and outputs

CS175-275-575-875 Installation Guide 119 3 Auxiliary power connection 7 X–10 Supervision LED 11 Relay 4 Keypad bus connection 8 X-10 Connection 2

Pagina 24

12 CS175-275-575-875 Installation Guide through the on-board electronic output, must be of SELV (Safety extra-low voltage) operating circuit. • Use a

Pagina 25 - 4.6.1 Inputs and outputs

120 CS175-275-575-875 Installation Guide Terminal Description Vout This terminal can supply up to 100 mA fused separate from the power in the control

Pagina 26

CS175-275-575-875 Installation Guide 121 20.3 Programming the CS507 20.3.1 Programming the output configuration and partition Location 0 Programmin

Pagina 27 - CS575 and CS875

122 CS175-275-575-875 Installation Guide  If set to follow condition, these events is 1 second.  Events 46 and 47 require RX8i4 - RX16i4 wireless

Pagina 28 - Ù key to determine the

CS175-275-575-875 Installation Guide 123 4 On: the event follows schedule 4. 5 On: the event follows schedule 5. 6 On: the event follows schedule

Pagina 29 - 5.2 Mounting the keypad

124 CS175-275-575-875 Installation Guide Location 32 Programming the opening time for schedule 1 (two segments, ND) Segment 1 Program the hour of the

Pagina 30 - 5.3 Wiring the keypad

CS175-275-575-875 Installation Guide 125 " The zone/user for the corresponding output must be "0" to use this location. The last bit o

Pagina 31

126 CS175-275-575-875 Installation Guide Location 75 Authorizing users 71 to 80 When activating outputs with a user code, this location can be used

Pagina 32 - 6 WIRING ZONES

CS175-275-575-875 Installation Guide 127 21 CS586 RS232 INTERFACE The CS586 is a low cost add-on module that fits neatly into any CSx75 system enclo

Pagina 33 - 7 WIRING SOUNDERS

128 CS175-275-575-875 Installation Guide Signal Name CS175 ------ PC Jumper number Pin number A position Pin number B position TXS - > J8 2 3

Pagina 34 - 7.3 AS271

CS175-275-575-875 Installation Guide 129 Location 0 Programming the option flag (one segment, FSD) The CS586 protocol can operate in one of two poss

Pagina 35 - 7.4 AS290/390

CS175-275-575-875 Installation Guide 13 defaulting and programming the control panel and the modules, adding users and setting authority levels. 7.

Pagina 36 - 8 WIRING FIRE DETECTORS

130 CS175-275-575-875 Installation Guide 22 CONTROL PANEL PROGRAMMING WORKSHEETS Factory defaults for segments are in bold italics and Quick Start loc

Pagina 37 - 8.2 Fire escape planning

CS175-275-575-875 Installation Guide 131 Seg#1 (Circle numbers to program) Seg#2 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 26 Dial attempts for phone

Pagina 38 - 9 WIRING THE OUTPUTS

132 CS175-275-575-875 Installation Guide 36 Zones 1-8, zone types 5-4-1-1-1-1-1-1 37 Zones 1-8, partition selection (Segment 1=zone 1 to segmen

Pagina 39

CS175-275-575-875 Installation Guide 133 Seg#4 (36) 1 Seg#5 (37) 1 Seg#6 (38) 1 Seg#7 (39) 1 Seg#8 (40) 1

Pagina 40 - 10 PROGRAMMING THE SYSTEM

134 CS175-275-575-875 Installation Guide 1 2 3 4 5 6 7 8 On: disables on-board 8 zones. On: force default configuration for zone types to be used.

Pagina 41

CS175-275-575-875 Installation Guide 135 Seg#2 (Circle numbers to program) 1 2 3 4 5 6 7 8 Enables Go to program code for partition #1. Enables

Pagina 42 - 10.2.8 Changing user codes

136 CS175-275-575-875 Installation Guide 67 Days of the week each partition is open Segments 1 2 3 4 5 6 7 8 Sunday Monday Tuesday Wednesday T

Pagina 43

CS175-275-575-875 Installation Guide 137 100 Expander trouble restore 0-0 101 Fail to communicate 0-0-0 102 Log full 0-0-0 103 Autotest 0-0-0

Pagina 44

138 CS175-275-575-875 Installation Guide Seg#5 – Reserved The defaults listed in the characteristic locations below represent the three segments of

Pagina 45

CS175-275-575-875 Installation Guide 139 166 Characteristic select 167 SIA code: Group 11 168 4/2 alarm code Seg#1-2-3: 0-0-0 169 4/

Pagina 46

14 CS175-275-575-875 Installation Guide 4.4 Installation schematic Connect all modules and keypads to the keypad bus Set module DIP switches and recor

Pagina 47

140 CS175-275-575-875 Installation Guide Seg#1-2: 0-0 202 Characteristic select 203 SIA Code: Group 20 204 4/2 alarm code Seg#1-2-

Pagina 48

CS175-275-575-875 Installation Guide 141 Seg#3 (51) 1 Seg#4 (52) 1 Seg#5 (53) 1 Seg#6 (54) 1 Seg#7 (55) 1

Pagina 49

142 CS175-275-575-875 Installation Guide Segments Part#1 Part#2 Part#3 Part#4 Part#5 Part#6 Part#7 Part#8 Seg#1 (89) 1 Seg#2 (90) 1

Pagina 50 - 11.2 Programming data

CS175-275-575-875 Installation Guide 143 Seg#4 (124) 1 Seg#5 (125) 1 Seg#6 (126) 1 Seg#7 (127) 1 Seg#8 (128

Pagina 51

144 CS175-275-575-875 Installation Guide Segments Part#1 Part#2 Part#3 Part#4 Part#5 Part#6 Part#7 Part#8 Seg#1 (161) 1 Seg#2 (162) 1

Pagina 52 - 12 PROGRAMMING THE PANEL

CS175-275-575-875 Installation Guide 145 23 APPENDIX 1: REPORTING FIXED CODES IN CONTACT ID AND SIA This table lists the event codes sent for the fol

Pagina 53 - 12.6.2 Exiting a location

146 CS175-275-575-875 Installation Guide Report Contact ID SIA Zone bypass (zone number) 570 *B Bypass restore (zone number) 570 *U Near Alarm (A/B

Pagina 54

CS175-275-575-875 Installation Guide 147 24 APPENDIX 2: REPORTING ZONE CODES IN CONTACT ID AND SIA The CSx75 can report SIA level 1 transmissions to

Pagina 55

148 CS175-275-575-875 Installation Guide SIA Contact ID 20 ZA Freeze Alarm 159 Low Temp

Pagina 56 - 13.2 Programming

CS175-275-575-875 Installation Guide 149 25 APPENDIX 3: OVERVIEW OF MODULE NUMBERS Every keypad, expansion module and wireless receiver module has a

Pagina 57

CS175-275-575-875 Installation Guide 15 INSTALLING THE CONTROL UNIT 4.4.1 CS575M/CS875M (large metal housing) This large metal housing can be used wi

Pagina 58

150 CS175-275-575-875 Installation Guide Address & DIP switch setting 24 (Switch 1 & 2 on) 28 (Switch 1, 2 & 3 on) 25 (Switch 3 on)

Pagina 59

CS175-275-575-875 Installation Guide 151 26 APPENDIX 4: SERVICE MESSAGES Message Explanation Control Over-current A short circuit of a control pan

Pagina 60

152 CS175-275-575-875 Installation Guide 27 GLOSSARY 24-hour zone This zone remains armed the whole time unless inhibited by forced arming. It reports

Pagina 61

CS175-275-575-875 Installation Guide 153 Automatic arming If programmed, the CSx75 auto arms at a specified time. At this time, the keypad beeps for

Pagina 62

154 CS175-275-575-875 Installation Guide Cancel If enabled, the CSx75 sends a cancel report if when the system is disarmed. Dialler Delay must be enab

Pagina 63

CS175-275-575-875 Installation Guide 155 Entry-guard A unique low level arming mode that reduces the most common source of false alarms. When armed,

Pagina 64

156 CS175-275-575-875 Installation Guide Force arming Arms the security system when a number of zones are open without inhibiting each one individuall

Pagina 65

CS175-275-575-875 Installation Guide 157 LED extinguish This feature extinguishes all LEDs on the keypad, except the Power LED, after 60 seconds with

Pagina 66

158 CS175-275-575-875 Installation Guide Silent exit option The exit delay can be silenced by pressing -Exit before arming the control panel or when

Pagina 67

CS175-275-575-875 Installation Guide 159 Two-call answering machine defeat If enabled, two telephone calls must be made to the premises to defeat an

Pagina 68

16 CS175-275-575-875 Installation Guide 9. Add the pillars for the CS507 output module or CS216 input expander or CS7001 to the box. 10. Mount the C

Pagina 69

160 CS175-275-575-875 Installation Guide 28 TECHNICAL SPECIFICATIONS Operating power Input 230 VAC ± 10% - 50 Hz ± 10% Fuse 230 V F315 mA, 20x5 Operat

Pagina 70

CS175-275-575-875 Installation Guide 161 Static Impulse Single loop 4k7: Disarmed Quiet Short Armed Change status Open: No reaction

Pagina 71

162 CS175-275-575-875 Installation Guide 29 TASKS SUMMARY Command Task Master User Code: 1122 User Code Installer Code: 1278  0 Set tone No code

Pagina 72

CS175-275-575 Manual 163 30 INDEX 25 VA transformer...59 2-wire smoke detectors...

Pagina 73

164 CS175-275-575-875 Installation Guide access ... 7 installer...

Pagina 74

CS175-275-575 Manual 165 Number of rings to answer...55 Numerical data...

Pagina 75

166 CS175-275-575-875 Installation Guide Walk test mode ...60, 134 Wireless transmitters setting options and par

Pagina 76

CS175-275-575 Manual 167

Pagina 77

CS175-275-575-875 Installation Guide 17 4.4.2 CS275/CS575/CS875 (polycarbonate housing) This polycarbonate housing can be used with the CS275, CS575

Pagina 78

18 CS175-275-575-875 Installation Guide 8. Flip down the PCB mounting tray. 9. Attach the pillars for the CS535 voice module to the board. 10. Atta

Pagina 79

CS175-275-575-875 Installation Guide 19 14. Drill 0.3 mm holes for the card guides in the box. 15. Place the card guide on the box. 16. Screw in the

Pagina 80

98/482/EC declaration (Applies to products that have the CE mark attached) This equipment has been approved in accordance with Council Decision

Pagina 81

20 CS175-275-575-875 Installation Guide Steps 1. Open the box. 2. Wire the panel. 3. Attach the pillars for the CS534 listen-in module or CS535 vo

Pagina 82

CS175-275-575-875 Installation Guide 21 6. Add the pillars for the CS216 input expander or CS507 output expander to the main board. 7. Mount the

Pagina 83

22 CS175-275-575-875 Installation Guide 4.5 Control unit wiring diagram: CS-175 1 Zones 1-4 6 External sounder 11 Serial expansion

Pagina 84

CS175-275-575-875 Installation Guide 23 4.5.1 Inputs and outputs CS175 DATA Communication/Expander data (0101) (Including Keypad) AUX + Communi

Pagina 85

24 CS175-275-575-875 Installation Guide 4.6 Control unit wiring diagram: CS-275 1 Zones 1-6 7 Open collector 1 12 Serial expansion 2

Pagina 86

CS175-275-575-875 Installation Guide 25 4.6.1 Inputs and outputs CS275 DATA Communication/Expander data (0101) (Including Keypad) AUX + Communica

Pagina 87

26 CS175-275-575-875 Installation Guide 4.7 Control unit wiring diagram: CS-575 and CS-875 1 Zones 1-8 7 Relay 1 12 Serial expansion

Pagina 88 - Type code to arm

CS175-275-575-875 Installation Guide 27 4.7.1 Inputs and outputs CS575 and CS875 DATA Communication/Expander data (0101) (Including Keypad) AUX +

Pagina 89

28 CS175-275-575-875 Installation Guide 5 LCD - LED KEYPAD Power (green) When lit, the system is powered up. Ready (green) The Ready LED is on w

Pagina 90 - Area 4 Ready

CS175-275-575-875 Installation Guide 29 Chime Press to turn the chime on and off. # Hash key Press to access modules and locations. * Star Press to

Pagina 91 - RX8i4-16i4

CS175-275-575-875 Installation Guide 3 CONTENTS 1 Introducing the CSx75 system ...

Pagina 92 - 16.3 Wiring the RX8i4-16i4

30 CS175-275-575-875 Installation Guide 5.3 Wiring the keypad The keypad should be wired to the control unit as follows. +-Com13.8V0101DataAux+ CSx75

Pagina 93

CS175-275-575-875 Installation Guide 31 In a star network, each keypad is wired back separately to the control unit terminals. 5.4.3 Star and multi

Pagina 94

32 CS175-275-575-875 Installation Guide 6 WIRING ZONES 6.1 General The control unit inputs are set up as standard EOL (4K7) freely programmable zones.

Pagina 95

CS175-275-575-875 Installation Guide 33 7 WIRING SOUNDERS 7.1 Wiring a sounder with EOL protection Any zone can be used. It should be programmed as

Pagina 96

34 CS175-275-575-875 Installation Guide 7.3 AS271 CSx75 AS271 1 Tamper 4 0 V speaker 2 Tamper 5 0 V beacon (AS271 only) 3 +13.8 V

Pagina 97 - 16.4.4 Deleting transmitters

CS175-275-575-875 Installation Guide 35 7.4 AS290/390 CSx75 AS290/AS390 1 Piezo 4 Beacon 7 GND 2 Piezo 5 Tamper 8 +13.8 V 3 Beacon 6

Pagina 98 - RX8w8-16w8

36 CS175-275-575-875 Installation Guide 8 WIRING FIRE DETECTORS 8.1 General If you need to drive more than one 4-wire fire detector, you may need to u

Pagina 99 - 17.3 Wiring the RX8w8-16w8

CS175-275-575-875 Installation Guide 37 8.1.3 4-wire fire detector (CS175) DB702 + DP721R DB702 + DP721R CS175 COMZ1AUX+COMSMOKE112

Pagina 100 - 17.3.2 Specifications

38 CS175-275-575-875 Installation Guide 9 WIRING THE OUTPUTS 9.1 Wiring the outputs The amount and type of available outputs is different per panel t

Pagina 101

CS175-275-575-875 Installation Guide 39 CS175

Pagina 102

4 CS175-275-575-875 Installation Guide 10.2.9 Assigning authority level ...

Pagina 103

40 CS175-275-575-875 Installation Guide 10 PROGRAMMING THE SYSTEM 10.1 Enrolling modules and keypads The CSx75 can automatically find and store in its

Pagina 104 - 17.4.4 Deleting transmitters

CS175-275-575-875 Installation Guide 41 1. Press 93. 2. Enter a Go to program code. 3. Set the keypad features listed in the following table. Pre

Pagina 105

42 CS175-275-575-875 Installation Guide 10.2.4 Setting elapsed increments since last autotest 1. Press 95. 2. Enter a Go to program code. 3. Enter

Pagina 106 - Setting the DIP switches

CS175-275-575-875 Installation Guide 43 4. Enter the new user code for the selected user. If you are changing the current code, use the scroll keys

Pagina 107 - 18.2 Wiring the CS216

44 CS175-275-575-875 Installation Guide 6. To remove access to a partition, press the partition number on the keypad. The partition is marked with a

Pagina 108 - 18.3 Programming the CS216

CS175-275-575-875 Installation Guide 45 Scroll keys Press to scroll through letters and lists on the keypad display. Stay Press to insert a space

Pagina 109 - 19 CS534 AUDIO BOARD

46 CS175-275-575-875 Installation Guide 2. Enter a Go to program code. 3. Enter the keypad number (1-8). The Bypass LED and the Service LED blink a

Pagina 110 - 19.2 Wiring the CS534

CS175-275-575-875 Installation Guide 47 2. Enter a Go to program code. 3. Enter [100's digit] -[10's digit]-[1's digit]-[#] and pres

Pagina 111 - 19.4 Line-hold or call back

48 CS175-275-575-875 Installation Guide Steps 1. Press 6. 2. Enter a master user code. The keypad prompts you to enter a user number. 3. Enter a t

Pagina 112 - 19.4.3 Control levels

CS175-275-575-875 Installation Guide 49 LED 2 is lit, the user can access partition 2. Press 2 to deny the user access to the partition and to turn o

Pagina 113 - 19.4.4 Tones

CS175-275-575-875 Installation Guide 5 16.4 Programming the RX8i4-16i4 ...

Pagina 114 - 19.5 Programming the CS534

50 CS175-275-575-875 Installation Guide 11 PROGRAMMING MODULES AND LOCATIONS 11.1 Parts of the system The system is divided into modules, locations,

Pagina 115

CS175-275-575-875 Installation Guide 51 • Several features can be selected from within one segment. For instance, if you want all eight features of a

Pagina 116

52 CS175-275-575-875 Installation Guide 12 PROGRAMMING THE PANEL 12.1 Default programming For most routine installations, the default programming allo

Pagina 117 - ADDRESS

CS175-275-575-875 Installation Guide 53 12.5 Defining the country code 1. Enter programming mode as described in Entering programming mode on page 5

Pagina 118 - OUPUT EXPANDER BOARD

54 CS175-275-575-875 Installation Guide • To program a module, enter its address and press #. See Selecting a module to program on page 52 for more in

Pagina 119 - Wiring the CS507

CS175-275-575-875 Installation Guide 55 • To program a module, enter its address and press #. See Selecting a module to program on page 52 for more i

Pagina 120 - 20.2.2 Specifications

56 CS175-275-575-875 Installation Guide 13 PROGRAMMING WITH UP/DOWNLOAD SOFTWARE 13.1 General You can program the CSx75 using the LED keypad, the LCD

Pagina 121 - 20.3 Programming the CS507

CS175-275-575-875 Installation Guide 57 14 CONTROL PANEL PROGRAMMING LOCATIONS Location Description 0 Country code Phone set up 1 Phone prefix 2 P

Pagina 122

58 CS175-275-575-875 Installation Guide Location Description 65 Opening time 66 Closing time/automatic arming time 67 Days of the week each partition

Pagina 123

CS175-275-575-875 Installation Guide 59 Location Description 152 4/2 alarm code group 7 153 4/2 restore group 7 154 Group 7 zone type characteristi

Pagina 124

6 CS175-275-575-875 Installation Guide 21.2.1 LED Indications...

Pagina 125

60 CS175-275-575-875 Installation Guide Location Description 232 Partition select, zones 105-112 233 Zones 113-120 zone type 234 Partition sele

Pagina 126

CS175-275-575-875 Installation Guide 61 Location 0 Country code (one segment, ND) This location contains the country code which sets the specific co

Pagina 127 - 21 CS586 RS232 INTERFACE

62 CS175-275-575-875 Installation Guide Location 3 Account code for phone #1 (six segments, ND) This location contains the account code sent when pho

Pagina 128 - 21.3 Programming the CS586

CS175-275-575-875 Installation Guide 63 3 Opening and closings 4 Zone bypass and bypass restores 5 Zone trouble and trouble restores 6 Power fail

Pagina 129

64 CS175-275-575-875 Installation Guide Tone dialling pager or Siren Tone formats. The factory default is 8. Location 27 Reserved Location 28 Dial

Pagina 130

CS175-275-575-875 Installation Guide 65 Location 33 Download call back number (16 segments, ND) If a telephone number is programmed in this locatio

Pagina 131

66 CS175-275-575-875 Installation Guide 7 Reserved 8 On: enables silent exit always. Segment 3 1 On: enables opening and closing reports. 2 On: en

Pagina 132

CS175-275-575-875 Installation Guide 67 Location 36 Zone type, zones 1 to 8 (eight segments, ND) Zones can be programmed to be one of twenty differe

Pagina 133

68 CS175-275-575-875 Installation Guide 8 Partition #8 Location 38 Zone type, zones 9 to 16 (eight segments, ND) This location contains the zone ty

Pagina 134

CS175-275-575-875 Installation Guide 69 Location 47 Partition select, zones 41 to 48 (eight segments, FSD) This location is used to select the part

Pagina 135

CS175-275-575-875 Installation Guide 7 1 INTRODUCING THE CSX75 SYSTEM The CSx75 range represents a new approach to security systems design. It is fle

Pagina 136

70 CS175-275-575-875 Installation Guide Location 51 System options (five segments, FSD) This location is used to enable various system feature and r

Pagina 137 - “B” Alarm

CS175-275-575-875 Installation Guide 71 5 On: enables end download report. 6 On: enables sensor low battery report. 7 On: enables sensor missing r

Pagina 138

72 CS175-275-575-875 Installation Guide and 99 (answer incoming call for download) functions. 3 Reserved 4 Enable walk-test mode 5-8 Reserved Lo

Pagina 139

CS175-275-575-875 Installation Guide 73 Location 57 Auxiliary output 1 to 4 partition selection (four segments, FSD) This location is used to selec

Pagina 140

74 CS175-275-575-875 Installation Guide Data Event Data Event 1  Fire alarm 22 Disarmed state 2  24-hour alarm 23 Ready 3  Trouble alarm 24

Pagina 141

CS175-275-575-875 Installation Guide 75  Events 49 and 50 require RX8w8, RX16w8, RX8i4 or RX16i4 wireless receivers to operate.  If set to the fol

Pagina 142

76 CS175-275-575-875 Installation Guide Location 65 Opening time (two segments, ND) This location contains the time, in 24-hour format, that the CSx7

Pagina 143

CS175-275-575-875 Installation Guide 77 2 Auto arming on Monday 3 Auto arming on Tuesday 4 Auto arming on Wednesday 5 Auto arming on Thursday 6

Pagina 144

78 CS175-275-575-875 Installation Guide Communicator Code Location Number of Segments Box trouble restore 79 2 Siren tamper 80 3 Siren tamper

Pagina 145 - CONTACT ID AND SIA

CS175-275-575-875 Installation Guide 79 Communicator Code Location Number of Segments End download 108 3 Locations 109 to 121 Reserved Locatio

Pagina 146

8 CS175-275-575-875 Installation Guide • Two partitions. • Integrated fire, access, verification and input/output modules. • Franklin 4+2, SIA, 200 ba

Pagina 147

80 CS175-275-575-875 Installation Guide 8 On: DTMF. Location 127 SIA code group 1 (one segment, ND) This location contains the event code sent for a

Pagina 148

CS175-275-575-875 Installation Guide 81 6 On: the zone type is included in the group shunt. 7 On: the zone type is force armable. 8 On: the zone t

Pagina 149 - 25.3 Output module CS507

82 CS175-275-575-875 Installation Guide Description 1 2 3 4 5 6 7 8 9 10 4/2 restore 169 173 177 181 185 189 193 197 201 205 Characteristics

Pagina 150

CS175-275-575-875 Installation Guide 83 3 Log event message 4 Keypad message received 5-8 Reserved Location 211 CS586 command/request enable (fou

Pagina 151 - PPENDIX 4: SERVICE MESSAGES

84 CS175-275-575-875 Installation Guide 6 Primary keypad function without PIN 7 Secondary keypad function 8 Zone bypass toggle Location 212 LCD ke

Pagina 152 - 27 GLOSSARY

CS175-275-575-875 Installation Guide 85 Location 221 Zone type, zones 81 to 88 (eight segments, ND) This location contains the zone type for zones

Pagina 153

86 CS175-275-575-875 Installation Guide Location 231 Zone type, zones 105 to 112 (eight segments, ND) This location contains the zone type for zones

Pagina 154

CS175-275-575-875 Installation Guide 87 Location 241 Zone type, zones 145 to 152 (eight segments, ND) This location contains the zone type for zone

Pagina 155

88 CS175-275-575-875 Installation Guide 15 USING PARTITIONED SYSTEMS Your system can be divided up so that it works in different ways in different are

Pagina 156

CS175-275-575-875 Installation Guide 89 2. The numbers on the top line represent the disarmed areas the code can access. The numbers on the bottom l

Pagina 157

CS175-275-575-875 Installation Guide 9 2 DEFAULT CODES Default installer code 1278 when using a four-digit code 127800 when using a six-digit code Lo

Pagina 158

90 CS175-275-575-875 Installation Guide All keys and functions entered affect this individual partition only. The LEDs and display represent the stat

Pagina 159

CS175-275-575-875 Installation Guide 91 16 SETTING UP RF ZONES – RX8I4-16I4 The RX-Series receiver modules add wireless capabilities to a CSx75 contr

Pagina 160 - 28 TECHNICAL SPECIFICATIONS

92 CS175-275-575-875 Installation Guide Module Number DIP Switch 1 DIP Switch 2 DIP Switch 3 DIP Switch 4 34 On On On Not Used 33 Off On On Not

Pagina 161

CS175-275-575-875 Installation Guide 93 Frequency 433 MHz for the RX8i4 and RX16i4 Current draw 20 mA Maximum Operating temperature 0 to 49 °C Dimens

Pagina 162 - ASKS SUMMARY

94 CS175-275-575-875 Installation Guide Location 1 Wireless sensor 1 characteristics (two segments, FSD) This location defines the characteristics

Pagina 163 - 30 INDEX

CS175-275-575-875 Installation Guide 95 Location 194 Starting zone (one segment, ND) Segment 1 0 Starting zone is zone 1 1 Starting zone is zone 9

Pagina 164

96 CS175-275-575-875 Installation Guide The following guidelines should be followed when programming the RX8i4-16i4 modules. • When a transmitter is

Pagina 165

CS175-275-575-875 Installation Guide 97 Repeater Press and then release the tamper switch. 16.4.4 Deleting transmitters The following steps describe

Pagina 166

98 CS175-275-575-875 Installation Guide 17 SETTING UP RF ZONES – RX8W8-16W8 The RX-Series receiver modules adds 868 MHz wirelless capabilities to a CS

Pagina 167 - CS175-275-575 Manual 167

CS175-275-575-875 Installation Guide 99 17.1 Setting the DIP switches Decide the starting zone of each zone expander. The starting zone must be on a

Commenti su questo manuale

Nessun commento