ATS2000/3000/4000/4500
Control Panel
Manager’s guide
Version 1.0, April 2003
Vedere la pagina 0
1 2 3 4 5 6 ... 70 71

Sommario

Pagina 1 - Control Panel

ATS2000/3000/4000/4500 Control Panel Manager’s guide Version 1.0, April 2003

Pagina 2

8 ATS2000/3000/4000/4500 Manager’s Guide Also, although users might be able to access a menu option, depending on how their PIN code has been progr

Pagina 3 - CONTENTS

ATS2000/3000/4000/4500 Manager’s Guide 9 DURESS The duress function activates a silent signal to alert security personnel. For example, if you are a

Pagina 4

10 ATS2000/3000/4000/4500 Manager’s Guide DOOR OPENING OPTION An Advisor MASTER keypad can be used to open a door by entering a door code. Your

Pagina 5 - WELCOME

ATS2000/3000/4000/4500 Manager’s Guide 11 When to arm You arm your premises, or areas in it, when they are unoccupied. Then if an unwanted event occ

Pagina 6 - THE ADVISOR MASTER KEYPAD

12 ATS2000/3000/4000/4500 Manager’s Guide Areas displayed: If the areas assigned to your PIN are displayed, any of those areas that are disarmed wi

Pagina 7 - The LED’s

ATS2000/3000/4000/4500 Manager’s Guide 13 DISARMING YOUR SYSTEM When to disarm If the area you want to enter is armed, you must first disarm the al

Pagina 8 - USER IDENTIFICATION

14 ATS2000/3000/4000/4500 Manager’s Guide From this display you have several options: Option Action Result Disarm all areas Press O and [ENTER]

Pagina 9

ATS2000/3000/4000/4500 Manager’s Guide 15 ACTIVE ZONES (WHEN ARMING) You cannot arm (or disarm, if your system is programmed that way) an area unles

Pagina 10

16 ATS2000/3000/4000/4500 Manager’s Guide TYPES OF ALARMS There are three types of alarms used in the Advisor MASTER system. 1. Local alarm 2. A

Pagina 11 - To activate duress

ATS2000/3000/4000/4500 Manager’s Guide 17 • The exact type of alarm (siren, flashing light, etc.) depends on how the system has been programmed. Yo

Pagina 12 - DOOR OPENING OPTION

Aritech is a GE Interlogix brand. www.aritech.com Copyright (c) 2003 GE Interlogix B.V.. All rights reserved. GE Interlogix B.V. grants the right

Pagina 13 - To arm the system

18 ATS2000/3000/4000/4500 Manager’s Guide WHAT TO DO WHEN THERE IS AN ALARM When there is an alarm, the LED of the area in alarm flashes red on th

Pagina 14 - Enter Area:

ATS2000/3000/4000/4500 Manager’s Guide 19 4. The display shows: Fix the problem (e.g. close the door).  Re-alarming: If your system has been p

Pagina 15 - DISARMING YOUR SYSTEM

20 ATS2000/3000/4000/4500 Manager’s Guide • If you are unable to reset an alarm because of a faulty zone, refer to the section Menu option 10, Inh

Pagina 16

ATS2000/3000/4000/4500 Manager’s Guide 21 LISTING PAST ALARM EVENTS This list provides you with a quick alarm history. It is a fast and easy way to

Pagina 17 - (WHEN ARMING)

22 ATS2000/3000/4000/4500 Manager’s Guide THE ADVISOR MASTER MENU The Advisor MASTER menu has 23 options available for performing various function

Pagina 18 - TYPES OF ALARMS

ATS2000/3000/4000/4500 Manager’s Guide 23 4. From the display you can now: Option Action Result Scroll forward Press [ENTER] Scrolls forward

Pagina 19

24 ATS2000/3000/4000/4500 Manager’s Guide 1. PANEL STATUS Use this function to list all zones that are in alarm, tamper alarm, inhibited or ac

Pagina 20 - Resetting a local alarm

ATS2000/3000/4000/4500 Manager’s Guide 25 2. ACTIVE ZONES Use this function to list all active zones. e.g. An open door. To list all active

Pagina 21 - Resetting a zone in alarm

26 ATS2000/3000/4000/4500 Manager’s Guide 3. ZONES IN ALARM Use this function to list all zones that are in alarm. Alarms must be acknowle

Pagina 22

ATS2000/3000/4000/4500 Manager’s Guide 27 4. INHIBITED ZONES Use this function to list all inhibited zones. You inhibit a zone to exclude it fro

Pagina 23 - LISTING PAST ALARM EVENTS

ATS2000/3000/4000/4500 Manager’s Guide 1 CONTENTS Welcome ...

Pagina 24 - THE ADVISOR MASTER MENU

28 ATS2000/3000/4000/4500 Manager’s Guide Example of one event: The top line of the display shows: • The time of the event in hours and minutes

Pagina 25 - 0-Exit, Menu:

ATS2000/3000/4000/4500 Manager’s Guide 29 6. TEST REPORT Use this function to display the results of the Disarm Test or Arm Test. Disarm tes

Pagina 26 - 1. PANEL STATUS

30 ATS2000/3000/4000/4500 Manager’s Guide DISARM TEST All zones tested successfully Untested zones Untested zones are listed either one at a ti

Pagina 27 - 2. ACTIVE ZONES

ATS2000/3000/4000/4500 Manager’s Guide 31 5. From the display you can now: Option Action Display the complete zone name Enter the zone number an

Pagina 28 - 3. ZONES IN ALARM

32 ATS2000/3000/4000/4500 Manager’s Guide To request the service menu 1. Access menu option 7. The display shows: 2. Enter your PIN code 3.

Pagina 29 - 5. HISTORY

ATS2000/3000/4000/4500 Manager’s Guide 33 Dial temporary management software This option allows a temporary telephone number to be programmed and di

Pagina 30 - To list the system history

34 ATS2000/3000/4000/4500 Manager’s Guide 9. LIST ZONE NAMES Use this function to display the zone names (text that describes the zones) in your sy

Pagina 31 - 6. TEST REPORT

ATS2000/3000/4000/4500 Manager’s Guide 35 10. INHIBIT ZONE Use this function to inhibit zones and exclude them from the security system. A zone is

Pagina 32

36 ATS2000/3000/4000/4500 Manager’s Guide 11. UNINHIBIT ZONE Use this function to uninhibit zones and include them again in the security system.

Pagina 33 - 7. SERVICE MENU

ATS2000/3000/4000/4500 Manager’s Guide 37 12. TEST ZONE Use this function to test if an individual zone is operating correctly. To test a zone

Pagina 34 - To request the service menu

2 ATS2000/3000/4000/4500 Manager’s Guide 23. Unlock, lock, disable and enable doors...

Pagina 35 - 8. FILM COUNTERS

38 ATS2000/3000/4000/4500 Manager’s Guide 13. START AUTO DISARM TEST Use this function to start the disarm test. To start the disarm test 1. A

Pagina 36 - 9. LIST ZONE NAMES

ATS2000/3000/4000/4500 Manager’s Guide 39 The test is completed The test is not completed 7. Press [ENTER] to return to the menu. 14. PROGR

Pagina 37 - 10. INHIBIT ZONE

40 ATS2000/3000/4000/4500 Manager’s Guide - Users 1001 to 11,466 can only have a card. To program user if two users are required 1. Access menu op

Pagina 38 - 11. UNINHIBIT ZONE

ATS2000/3000/4000/4500 Manager’s Guide 41 The display shows the user's door group. e.g. 4. Press [ENTER] The display shows the user's fl

Pagina 39 - 12. TEST ZONE

42 ATS2000/3000/4000/4500 Manager’s Guide 3. Do one of the following options: Option Action Select the number of the alarm group to be issued to

Pagina 40 - 13. START AUTO DISARM TEST

ATS2000/3000/4000/4500 Manager’s Guide 43 Passback" restrictions on Doors 17 to 64. Extended Access If set to YES, the user will be allowed ext

Pagina 41 - 14. PROGRAM USERS

44 ATS2000/3000/4000/4500 Manager’s Guide 8. If the user number that you are programming is higher than 1000, then all options available have been

Pagina 42 - To display a user

ATS2000/3000/4000/4500 Manager’s Guide 45 3. You cannot program a PIN code or user number that already exists. 4. You cannot program a PIN code th

Pagina 43

46 ATS2000/3000/4000/4500 Manager’s Guide If their Alarm Group option “Change own PIN code” is set to ‘NO’, then the user has access to all the st

Pagina 44 - Floor Group:

ATS2000/3000/4000/4500 Manager’s Guide 47 15. TIME AND DATE Use this function to program a new time and date. The time and date are not visibl

Pagina 45

ATS2000/3000/4000/4500 Manager’s Guide 3 WELCOME This manual explains how to use the Advisor MASTER system if you are responsible for managing the

Pagina 46 - PIN Code:

48 ATS2000/3000/4000/4500 Manager’s Guide The display shows: 4. Enter the correct day (2 digits) and press [ENTER]. The display shows: 5. Ent

Pagina 47 - Change own PIN code

ATS2000/3000/4000/4500 Manager’s Guide 49 4. Enter the month number and press [ENTER], [ENTER] 5. Select: 1: DST end at FIRST Sunday of the mon

Pagina 48

50 ATS2000/3000/4000/4500 Manager’s Guide To inhibit/uninhibit RASs/DGPs 1. Access menu option 16. The display shows: 2. Enter 1 for RAS or 2 f

Pagina 49 - 15. TIME AND DATE

ATS2000/3000/4000/4500 Manager’s Guide 51 Option Action Enable the Service Technician's code for the programmed time period, and return to the

Pagina 50

52 ATS2000/3000/4000/4500 Manager’s Guide To program door and floor groups 1. Access menu option 20. The display shows: 2. Select the option yo

Pagina 51 - NHIBIT/UNINHIBIT RAS/DGP

ATS2000/3000/4000/4500 Manager’s Guide 53 Floor groups: (if you selected option number 2) 1. The display shows: Enter the floor group number and

Pagina 52

54 ATS2000/3000/4000/4500 Manager’s Guide 21. HOLIDAYS Use this function to record the date of holidays. The holidays recorded here can be used in

Pagina 53 - 20. DOOR AND FLOOR GROUPS

ATS2000/3000/4000/4500 Manager’s Guide 55 22. OPEN DOORS Use this function to open a valid door via the LCD arming station. To open a door via

Pagina 54

56 ATS2000/3000/4000/4500 Manager’s Guide 2. Enter the door function option you want to do and press [ENTER], or Press [ENTER] to return to the m

Pagina 55

ATS2000/3000/4000/4500 Manager’s Guide 57 24. PRINT HISTORY Use this function to instruct the control panel to print the complete system history f

Pagina 56 - 21. HOLIDAYS

4 ATS2000/3000/4000/4500 Manager’s Guide THE ADVISOR MASTER KEYPAD Figure 1: The keypad The keypad  0 - 9 • Used to enter alphanumeric informat

Pagina 57 - 22. OPEN DOORS

58 ATS2000/3000/4000/4500 Manager’s Guide PROGRAMMING RECORDS Use the following pages to record details of the relevant data programmed for your s

Pagina 58 - Door No:

ATS2000/3000/4000/4500 Manager’s Guide 59 USER RECORD – MENU OPTION 14 Use this page to record details of the relevant user data for your system. B

Pagina 59 - 24. PRINT HISTORY

60 ATS2000/3000/4000/4500 Manager’s Guide DOOR GROUP RECORD – MENU OPTION 20 Door Group N°: Door N°: Time zone: Door N°: Time zone: 1 33 2

Pagina 60 - PROGRAMMING RECORDS

ATS2000/3000/4000/4500 Manager’s Guide 61 FLOOR GROUP RECORD – MENU OPTION 20 Floor Group N°: Floor N°: Time zone: Floor N°: Time zone: 1 33

Pagina 61 - USER RECORD – MENU OPTION 14

62 ATS2000/3000/4000/4500 Manager’s Guide HOLIDAY RECORD – MENU OPTION 20 Holiday Number: Number Date / / Day Month Year Holiday Num

Pagina 62

ATS2000/3000/4000/4500 Manager’s Guide 63 ALARM GROUP RECORD DETAILS TO BE SUPPLIED BY THE INSTALLER Number: Name: Function Summary:

Pagina 63

64 ATS2000/3000/4000/4500 Manager’s Guide TIMEZONE RECORD DETAILS TO BE SUPPLIED BY THE INSTALLER Timezone Number .1 Start End

Pagina 64

ATS2000/3000/4000/4500 Manager’s Guide 65 GLOSSARY Access control The control of entry to, or exit from, a security area. Active See Normal/Active/

Pagina 65 - ALARM GROUP RECORD

66 ATS2000/3000/4000/4500 Manager’s Guide each floor in a group can be restricted via a timezone. History A list of past alarm and access control

Pagina 66 - TIMEZONE RECORD

ATS2000/3000/4000/4500 Manager’s Guide 67 INDEX Active zones when arming/disarming, 15 Adding a user to the system, 39 Advisor MASTER menus accessi

Pagina 67 - GLOSSARY

ATS2000/3000/4000/4500 Manager’s Guide 5  + or + [CLEAR] + (▲) [CLEAR] + (▼) • Increases the keypad buzzer volume. • Decreases the keypad bu

Pagina 68

68 ATS2000/3000/4000/4500 Manager’s Guide description, 6 restrictions when using, 7 using, 7 Programming record sheets, 58 user records, 59 Program

Pagina 69

ATS2000/3000/4000/4500 Manager’s Guide 69

Pagina 70

6 ATS2000/3000/4000/4500 Manager’s Guide ON The area is unoccupied and armed. OFF The area is occupied and the security system has been set to allo

Pagina 71